Steam turbine-powered feed water pump, CHP plant Čáslav, Czechia
Owner's Engineer |
Design and Studies |
Installation and Supply |
Diagnostics |
|
✓ |
|
|
We developed conceptual design and feasibility study on various steam turbine-powered feed water pump concepts.
BFS Industry activities:
- Optimization of the turbine implementation in to the existing CHP plant
- Elaboration of feasibility study
- Elaboration of conceptual design
Execution date: 01/2016 - 03/2016
Technical specifications of the turbine:
- Steam turbine mechanical power: 125 kW
- Inlet steam pressure: 6.2 MPa(g)
- Outlet steam pressure: 0.16 MPa(g)
- Inlet steam temperature: 465 °C